Model Number : 4HS+
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time : 3-5 work days
Operating Principle : 3-electrode electrochemical
Measurement Range : 0-100 ppm H2S
Maximum Overload : 500 ppm H2S
Sensitivity* : 0.7 ± 0.15 μA/ppm
Response Time (T90)* : 20 seconds
Baseline Offset (clean air)* : < ±0.5 ppm equivalent
4HS+ Hydrogen Sulfide (H2S) Gas Sensor Part Number: 2112B2025 Industry leading reliability
IMPORTANT NOTE:
Connection should be made via PCB sockets only.
Soldering to the pins will seriously damage your
sensor and invalidate the warranty.
All performance data is based on conditions at
20°C, 50%RH and 1013mBar, using City Technology
recommended circuitry. For sensor performance data
under other conditions, please contact City Technology.
Storage Life | 6 months in sealed container |
Expected Operating Life | 2 years in air |
Recommended Storage Temp | +10°C to +30°C |
Long Term Output Drift | < 20% per annum |
Maximum s/c Current | <1.0 A |
![]() |